MeanWell LRS-350-5 Switching LED Video Screen Power Supply (5V 60A 300W).
Rasti:806 Madhësia:215×115×30mm.
Fuqia: 300W.
100% Testi i djegies me ngarkesë të plotë
Universal AC input/ full range
Funksioni aktiv PFC i integruar, PF>0.95
Mbrojtjet: Short circuit/ Over load/ Over voltage
Treguesi LED për ndezje
1 vit garanci
UL kaloi
MeanWell LRS-350-5 Switching LED Video Screen Power Supply Product Specifications :
Model | LRS-350-5 | |
Input | Voltage Range | 85~ 264VAC 120~ 370VAC |
FREQUENCY RANGE | 47 ~ 63Hz | |
AC CURRENT (Tip.) | 3.5A/115VAC 1.5A/230VAC | |
RRYMË E RRJEDHJES | <2mA / 240VAC | |
INRUSH RRYMË (Tip.) | COLD START 65A/230VAC | |
EFIÇENCA (Tip.) | 83% | |
Prodhimi | AKTUALE E VLERËSUAR | 60A |
TENSION DC | 5V | |
FUQI E VLERËSUAR | 300W | |
FARM AKTUALE | 0-60A | |
VOLTAGED ADJ. GAME | 4.5~ 5.5V | |
RREGULL & ZHURMA (maksimumi) Shënim.2 | 150mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±2,0% | |
LOAD REGULATION Note.5 | ±1.5% | |
LINE REGULATION Note.4 | ±0,5% | |
MBANI KOHEN | 20ms at full load | |
SETUP, RISE TIME | 600ms,40ms at full load | |
Mbrojtja | OVER VOLTAGE | 5.75~ 6.75V Lloji i mbrojtjes :Shut off 0/p volltage, clamping by zener diode |
OVER LOAD | Above 150% rated output power Lloji i mbrojtjes :Hiccup mode, recovers automatically after fault condition is removed |
|
Siguria | TË QËNDROJNË TENSIONIN | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
SAFETY STANDARDS Note 6 | UL60950-1, CB(IEC60950-1),CCC GB4943, 1:2011 miratuar | |
REZISTENCA NË IZOLIM | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH | |
STANDARDET EMC | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, GB9254 | |
Environment | Lagështia e punës | 20 ~ 90% RH non-condensing |
TEMP PUNËS | -20 ~ +70 (Refer to output load derating curve) | |
TEMP. KOEFICIENTI | ± 0.03%/ | |
STORAGE TEMP., LAGËSHTIA | -40 ~ +85 , 10 ~ 95% RH | |
VIBRIMI | 10 ~ 500 Hz, 2G 10min./1cycle, 60min. secili përgjatë X, Y, akset Z | |
Të tjerët | DIMENSIONI | 215*115*30mm (L*W*H) |
MTBF | 1608.8K hrs min. MIL-HDBK-217F (25 | |
Shënim | I. Al parameters NOT specialy mentioned are measured at 230VAC input. rated load and 25??of ambient temperature. 2 Ripple & noise are measured at 20MHz Of bandwidth by usig a I2??twisted pair-wire terminated with a 0.1UI & 470 Parallel capacitor 3. Tolerance : includes set up tolerance. line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% te 100% rated load. 6. For the request of GEl4943.1.the power soppy is only suable for use in the altitude 2000m below and the non tropical climate condrtion. 7. The power supply is considered a component which will be instated into a final equipment The final equipment must be re-confirmed that it still mesh EMC drectives. For guidance on how to perform the EMC tests. please refer to ‘EMI testing of component power supplies??/td> |
Shqyrtime
Nuk ka ende komente.