MeanWell LRS-350-5 Switching LED Video Screen Power Supply (5V 60A 300W).
Geval:806 Maat:215×115×30mm.
Stroom: 300W.
100% Inbrandtest bij volledige belasting
Universal AC input/ full range
Ingebouwde actieve PFC-functie, PF>0.95
Beveiligingen: Short circuit/ Over load/ Over voltage
LED-indicator voor inschakelen
1 jaar garantie
UL geslaagd
MeanWell LRS-350-5 Switching LED Video Screen Power Supply Product Specifications :
Model | LRS-350-5 | |
Invoer | Voltage Range | 85~ 264VAC 120~ 370VAC |
FREQUENCY RANGE | 47 ~ 63Hz | |
AC CURRENT (Typ.) | 3.5A/115VAC 1.5A/230VAC | |
LEKKAGE STROOM | <2mA / 240VAC | |
INRUSH-STROOM (Typ.) | COLD START 65A/230VAC | |
EFFICIËNTIE (Typ.) | 83% | |
Uitvoer | GENOMINEERDE STROOM | 60A |
DC-SPANNING | 5V | |
NOMINAAL VERMOGEN | 300W | |
HUIDIG BEREIK | 0-60A | |
VOLTAGED ADJ. BEREIK | 4.5~ 5.5V | |
RIMPELING & LAWAAI (maximaal) Opmerking.2 | 150mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±2,0% | |
LOAD REGULATION Note.5 | ±1.5% | |
LINE REGULATION Note.4 | ±0,5% | |
HOUD TIJD | 20ms at full load | |
INSTELLING, RISE TIME | 600mevrouw,40ms at full load | |
Bescherming | OVER VOLTAGE | 5.75~ 6.75V Beschermingstype :Shut off 0/p volltage, clamping by zener diode |
OVER LOAD | Above 150% rated output power Beschermingstype :Hiccup mode, recovers automatically after fault condition is removed |
|
Veiligheid | Bestand tegen spanning | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
SAFETY STANDARDS Note 6 | UL60950-1, CB(IEC60950-1),CCC GB4943, 1:2011 goedgekeurd | |
ISOLATIEWEERSTAND | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RV | |
EMC-NORMEN | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, GB9254 | |
Environment | WERKVOCHT | 20 ~ 90% RH non-condensing |
WERKTEMP | -20 ~ +70 (Refer to output load derating curve) | |
TEMP. COËFFICIËNT | ± 0.03%/ | |
STORAGE TEMP., VOCHTIGHEID | -40 ~ +85 , 10 ~ 95% RV | |
TRILLING | 10 ~ 500 Hz, 2G 10min./1cycle, 60min. elk langs X, Y, Z-assen | |
Anderen | DIMENSIE | 215*115*30mm (L*B*H) |
MTBF | 1608.8K hrs min. MIL-HDBK-217F (25 | |
Opmerking | I. Al parameters NOT specialy mentioned are measured at 230VAC input. rated load and 25??of ambient temperature. 2 Rimpeling & noise are measured at 20MHz Of bandwidth by usig a I2??twisted pair-wire terminated with a 0.1UI & 470 Parallel capacitor 3. Tolerance : includes set up tolerance. line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% naar 100% rated load. 6. For the request of GEl4943.1.the power soppy is only suable for use in the altitude 2000m below and the non tropical climate condrtion. 7. The power supply is considered a component which will be instated into a final equipment The final equipment must be re-confirmed that it still mesh EMC drectives. For guidance on how to perform the EMC tests. please refer to ‘EMI testing of component power supplies??/td> |